Your quote Your quote

PFU-00

Fire-Rated Insulated Upward Opening Access Door with Exposed Flange

hex head slam latch and ring key operated slam latch, piano hinge

The fire rated insulated upward opening access door can be used on fire rated ceilings.

  • Installation Ceilings
  • Material Galvanneal steel
  • Locking mechanism Hex head slam latch and ring key operated slam latch
  • Hinge Piano hinge
  • Flange Exposed flange
  • Size Other sizes available upon request

Quantity

Specifications

  • Material

    20-gauge galvanneal steel door 16 gauge cold rolled steel frame

  • Hinge

    Continuous piano hinge. Hinge location: Hinges must be located on the second dimension (height).

  • Locking mechanism

    Hex head slam latch outside and a self-latching ring operated slam latch inside

  • Flange

    1" exposed flange

  • Frame

    3" in depth, made of cold rolled steel

  • Rough opening

    Door sizes + ¼" or + 6mm

  • Insulation

    2" thick fire rated mineral wool

  • Finish

    High quality white powder coat primer.

  • Packaging

    Individually wrapped, 1 door per box.

  • Fire rated access doors, for horizontal use, are subject to the following:
    • Horizontal ceiling assemblies

      Fire rated access doors, for horizontal use, are subject to the following:

    • Certification

      ASTM E119 (2012), CAN/ULC S101 (2007)

    • Rating Achieved

      3 hours in non-combustible construction and 1 hour in combustible construction

    • Maximum size

      24"X36" (610 mm X 914 mm) (hinges and latches on the side of 36"), tolerance on dimension limitations are more or less 3" (76 mm) as long as the area does not exceed 864 in².

    • Temperature rise

      Not applicable

Dimensions

Dimensions (Inches)Dimensions (Millimeters)Weight (LBS)Weight (KG)Number of locks
* 22 x 30558 x 76233.315.11
* 22 x 36558 x 91439.217.82
* All dimensions are written in the following order: Width X Height